Nueces Desalination Center: Production of Drinking Water by Multi-Stage Flash Distillation

From processdesign
Jump to navigation Jump to search

Team F: Rankine 672 Final Report

Authors: Kedric Daly, Ben Granger, Evan Rosati, Kathleen Zhou

Instructors: Fengqi You, David Wegerer

March 11, 2016

Executive Summary

Desalination of seawater to drinking water is a technology of ever-increasing importance given trends of increasingly widespread water shortages around the world. Even in the United States, water shortages are becoming increasingly common in dry, highly-populated such as California and certain areas of the Gulf Coast. Our design team, Rankine 672, was tasked with evaluating the need for and designing a desalination plant to provide purified water in a place of need. Investigation revealed that the city of Corpus Christi, Texas, is a strategic location for development of a desalination facility, as surrounding region is in need of new drinking water sources and the city has expressed serious interest in contracting the development of a large-scale desalination plant. Our proposed solution is a multi-stage flash distillation desalination facility capable of producing 20,000,000 gallons (75,708 m3) of purified drinking water for the city and surrounding region per operating day.

In this design, drinking water is produced from seawater feedstock through a 21-stage flash distillation process. By strategically locating the facility next to an existing natural gas power plant, the Nueces Bay Energy Center, pre-heated feed water can be taken directly from the outbound cooling systems of the power plant, allowing energy savings for our desalination plant. The process is designed for 16 hour-per-day operation, requires a seawater feed of 8250 m3/hr, and produces 4758 m3/hr of purified drinking water alongside a waste stream of 3485 m3/hr of concentrated brine. The waste stream is isolated from a recycle stream through a 9.0% purge; this results in an overall product yield of 57.7% on a volume basis. The process requires an additional pretreatment stream of 16.5 kg/hr Belgard EV 2030, which serves as an antiscalant, as well as 9.5 kg/hr chlorine, 352.1 kg/hr lime, and 418.7 kg/hr CO2 for post-treatment purposes.

The overall capital cost of the plant is expected to be $345MM, with a total operating cost of $103MM/yr, $59MM/yr of which comes from utilities. Due to the low price at which the product water can be sold, the 30-year net present value of the plant, assuming a 6% discount rate, is $-1,035MM. It is thus imperative this plant be constructed with public funds because it cannot return a profit to any private investor. The growing need for water however could justify the cost, because it is important that the residents of the greater Corpus Christi area have access to drinkable water.

Introduction

Background

Clean drinking water is a basic human need that is becoming increasingly difficult to meet. Currently, over 1 billion people live in places where water is considered scarce[1]. Though often thought of as a problem exclusive to third-world countries, the issue is becoming more prevalent in the US as well, with water managers in 40 of 50 states anticipating water shortage conditions in some portion of their state in the next 10 years. These shortages are due to increasing demands on constant or diminishing freshwater resources, therefore, to correct the issue, a new supply must be found[2]. Desalination of seawater is therefore important as a new source for clean drinking water and prevent water shortages.

Project Definition

The overall goal of the project is to investigate the feasibility of a desalination plant in order to meet the needs of growing water demand. The design needs to take health, safety, and environmental concerns into account, while optimizing costs.

Design Basis

Site Location and Conditions Corpus Christi, TX was chosen as the location for the proposed desalination plant. The city is currently experiencing “Moderate Shortage Conditions”. This issue additionally comes at a time of growing demand with population growth anticipated due to new industry and Eagle Ford Group crude oil production[3].

In June 2014, the city announced the Corpus Christi Desalination Demonstration Project[4] which seeks to create a demonstration desalination plant capable of producing 20,000 gallons of water per day, with plans to later build a full scale facility generating 20,000,000 gallons of water per day. The desalination demonstration project indicates a clear need for implementation of a desalination plant of this size to accommodate growth in the Corpus Christi area.

Locating our plant in Corpus Christi will allow us to take advantage of the benefits of cogeneration through a partnership with the Nueces Bay Energy Center. By utilizing their outlet cooling water as a large portion of our feed for the desalination process, we can raise the temperature of our seawater feed, saving on energy costs in the multi stage flash distillation. The proposed location for the desalination plant is immediately west of the Nueces Bay Energy Center. See Appendix A for a map depicting the proposed location for the desalination plant along the coast of Nueces Bay.

Feed and Product Definitions

The proposed desalination facility’s feed and product streams are defined as shown in Table 1. Rationale for these definitions is also described below. The values reported in Table 1 are final derived numbers from HYSYS simulation modeling.

Table 1: Feed and product stream definitions
  Salt Concentration Temperature Amount
Feed Stream 30,500 ppm 45°C 8250 m3/hr
Product Stream ~ 0 ppm 35°C 4758 m3/hr
Byproduct Stream 69,500 ppm 35°C 3485 m3/hr

The process feed will be seawater from Nueces Bay, preheated through the cooling water system of the nearby Nueces Bay Energy Center. Based on calculations developed from NREL (National Renewable Energy Laboratory) data, it was estimated that the Nueces Bay Energy Center uses approximately 250 million gallons of seawater per day for process and cooling needs. Therefore, the 20 million gallon per day requirement for the desalination facility can easily be met through the power plant’s cooling water[5]. Note that we are assuming the process will operate 67% of the time (16 hours per day).

Based on data acquired from two salinity-measuring stations in Nueces Bay, the average salinity of local seawater is 30.5 practical salinity units (psu)[6], thus setting the concentration of the process feed stream. This translates to a feed stream concentration of 30,500 ppm (parts per million)[7]. The composition of the salt attributed to this seawater salinity is shown in Table 6 in Appendix B.

No data on the composition of seawater around the Corpus Christi area was available, but the composition of seawater does not change significantly in different locations. The given composition is considered accurate for our feed stream[8]. Note that seawater salt is primarily sodium chloride - total dissolved solids are 85.7% sodium chloride by mass. As such, the dissolved solids in the feed stream is assumed in this project to be pure NaCl, making the feed composition 96.95% water and 3.05% NaCl by mass. A control system will likely be put in place to ensure feed concentration remains at this level, accounting for natural fluctuations in local seawater salinity.

The largest byproduct from the process will be a brine slurry with high salt concentrations. An upper corrosion limit of 700 ppm was set for recirculated and purged brine. This undesired byproduct will be sent to a nearby Class I non-hazardous injection well facility operated by GNI Group, which is approximately 12 miles away from the proposed desalination plant location as shown in the figure in Appendix A[9][10]. Through the incorporation of a Class I injection well, the brine will not have to be treated or diluted before injection. [11][12]

There are no regulations regarding the temperature of city drinking water, so the product stream temperature has no requirements based on regulations. Outlet temperatures of 35oC are acceptable for input to the municipal water supply system. Since city water tends to be stored in non-temperature controlled tanks, the temperature will naturally cool to ambient temperature.[13]

Pre-Treatment and Post-Treatment

For pretreatment, Belgard EV 2030 is recommended to be added at a concentration of 1.8-2.0 mg/L for a system with top brine temperature approximately 110 °C[14]. Since our process is designed to operate at a slightly higher top brine temperature, 120 °C, we will design for the upper bound concentration: 2.0 mg/L of antiscalant. With a feed flow rate of 8250 m3/hr, the process therefore requires 16.5 kg/hr of Belgard EV 2030.

For disinfection during post-treatment, chlorine addition typically requires a dose of roughly 2.0 mg/L as well[15]. With a pure water distillate flow rate of 4758 m3/hr, the process requires 9.5 kg/hr of chlorine as a 5%-15% sodium hypochlorite solution. Approximately 74 mg/L of lime (calcium hydroxide) and 88mg/L of CO2 should be added to the desalinated water to help prevent corrosion and increase alkalinity within acceptable ranges[16]. With a product stream flow rate of 4758 m3/hr, these concentrations correspond to 352.1 kg/hr of lime and 418.7 kg/hr of CO2. Both of these can be purchased, and it is likely that the CO2 can be procured from the neighboring natural gas power plant.

Choice of Desalination Technology

The two major technologies commonly implemented for desalination include reverse osmosis (RO), and multi-stage flash distillation (MSFD). RO utilizes high pressures to force water through a semipermeable membrane that allows for purified water to pass through, but stops organic and other wastes. Often, the pressures can reach 55 - 68 bar, which requires large pumps to maintain pressure, and introduces safety concerns to the process[17]. While RO can be less energy intensive than MSFD, and the membrane can also remove contaminants, it is susceptible to feedwater quality, membrane fouling, and requires more extensive pretreatment and posttreatment than MSFD. The cost of RO is directly proportional to the feed salinity, and so it is less expensive when desalinating low salinity water.

Multi-stage flash distillation is best selected for areas that have high salinity or low energy costs. The pretreatment process for MSFD is much easier when compared to RO because pretreatment often consists of simply adding anti-corrosives and antiscalants to the feed stream. The process works by heating water in vessels at different pressures to change the boiling point of the water and evaporate it as it passes through the system. After evaporation, the water condenses, leaving pure water as the effluent. MSFD costs are now roughly $1.00/m3, where this cost is mostly independent of salinity, but dependent on energy costs.[18] In both RO and MSFD a brine is produced which then must be appropriately treated and/or disposed of.

Multi-stage flash distillation was selected for this process, mainly due to the economic advantages offered by the selected location of Corpus Christi, TX. MSFD is also a well understood process that can be more easily modeled by chemical engineering software.

Technical Approach

Quantitative modeling of the process and all included optimization was conducted using the simulation software Aspen HYSYS. A variety of assumptions were developed to set up and define specific components of the process simulation itself. Within Aspen HYSYS, the NRTL Electrolyte property package was selected to model the behavior of salt water. Each stage of the MSF process is modeled as an individual flash vessel, with individual shell & tube heat exchangers used to model the distillate condensers present in each flash stage in the MSF system.

The HYSYS simulation model only considers the flash portion of the overall process, allowing establishment of mass and energy balances for the system. Pretreatment and post-treatment were excluded for the HYSYS model, as these steps are simple additions or removals of small concentrations of chemical components. Although the simulation models heat exchangers outside of each flash stage, in the physical design of the plant these heat exchangers will be contained within each flash stage.

One portion of the process is not modeled, which is the inlet seawater entering the heat rejection stages. As can be seen from the full process flow diagram (Appendix C), the inlet seawater in the heat rejection stage is in high excess to provide maximum cooling capacity; then a significant portion is purged to bring the stream flow rate down to what is needed for the feed stream. It is assumed that the flow rate of cooling water for those three stages is in such high excess that the cooling water does not heat up. Therefore, in the process simulation models, the inlet stream is the feed stream, which enters directly into the heat recovery portion of the process.

See Appendix D for a screenshot overview of the simulation environment model.

Process Overview

Process Flowsheet

The following diagram, Figure 1, shows a basic flowsheet for the process. Process alternatives considered for each stage are discussed below. Please see Appendix C for the full process flowsheet with finalized design decisions.

Nueces Bay Desalination Facility Block Flow Diagram
Figure 1: Basic block flowsheet of the multi-stage flash desalination process.

Major Features

As seen above, there are three primary stages of the desalination process: Pre-treatment, the multi-stage flash distillation, and post-treatment. Seawater enters the pre-treatment phase first to make the feed suitable for the rest of the process by filtering out large particles that could accumulate on pipes, deaerating the water to limit corrosion, and adding an agent to combat fouling. The water then enters the distillation process, which is broken up into two sections: heat recovery and heat rejection.

In the heat recovery stage, there are 18 flash vessels, each of which separates steam from the salinated liquid water. Each flash vessel has saltwater as its inlet and two outlets: a vapor outlet (steam) that condenses into the final product of purified water and a liquid outlet composed of water with more dissolved solids than the inlet, which is the inlet stream for the next flash vessel. The pipe containing the feed is first mixed with recycled brine, then goes through the top sections of each of the flash vessels, starting with V-118 and ending up at V-101. In this way, the feed stream pipe first serves as a heat exchanger, heating the pre-treated seawater while simultaneously condensing the steam into the final product. The feed then enters a final heat exchanger where it is brought up to 103.6 °C before entering V-101 to be flashed.

After exiting V-118, the final flash vessel in the heat recovery portion, the water enters the heat rejection portion, which consists of three flash vessels (V-201, V-202, V-203). The flash vessels of this section operate in the same manner as in the heat recovery section, with the exception that condensation occurs using excess cooling water instead of pre-treated seawater. This technique allows excess heat to be rejected into an excess water stream rather than the feed.

The purified product stream finally enters post-treatment processing in which water is re-aerated and remineralized, disinfected, and pH is adjusted before being delivered to the city. The concentrated brine leftover at the end of the flash cycle is recycled into the feed, although a purge is required to continuously remove some salt from the system. This purged brine is disposed of by use of a Class I injection well, per regional regulations.

See Appendix E to find detailed stream tables of stream specifications.

Process Alternatives

Pretreatment

Multi-stage flash distillation requires significantly less pretreatment than reverse osmosis desalination, but helpful pretreatment techniques still exist. One very inexpensive method of pretreatment is screening/filtration, which is used to filter out large contaminants from intake seawater. Using more complicated membrane technology to accomplish large particle filtration is a possible alternative, but doing so would be much more expensive than using a standard screen or filter, so the latter choice has been selected for this process.[19]

The most critical type of fouling in multi-stage flash distillation is scaling - therefore, the most critical step in the pretreatment process will be the inclusion of an anti-scalant. Alkaline scaling can be prevented by acid dosing or polyphosphate addition; however, acid dosing can result in increased corrosion and polyphosphates can lead to non-alkaline calcium phosphate fouling, so these additives will not be considered[20][21]. As such, a polymer-based additive is recommended for the anti-scalant for this process. The Belgard EV series is designed for use in high-temperature seawater MSF; of these, Belgard EV 2030 is the most neutral in pH[22][14][23][24]. As such, we have selected Belgard EV 2030 for use as an anti-scalant in our process.

Corrosion control is another significant method of pretreatment in multi-stage flash distillation plants. Using a piping material that has limited susceptibility to corrosion is typically not economically viable for MSF desalination plants due their large size, so using carbon steel for most of the piping is generally used for its economic benefits despite its susceptibility to corrosion[20]. Limiting oxygen concentration is very feasible through the use of deaerators, which can remove oxygen as well as other dissolved gases from the seawater stream. Often, an external deaeration system is used[20][25]. Given these considerations, using an external deaerator combined with a less-corrosive antiscalant like Belgard EV 2030 is much more practical for the process than using anti-corrosive piping.

Excessive foam can also be an issue in some MSF distillation facilities, so antifoaming agents are sometimes employed in the pretreatment process as well. However, many plants are operated without foaming issues, and therefore do not need anti-foaming pretreatment at all. Selection of an anti-foaming agent must be carefully weighed with selected of anti-scalant to avoid issues with additive interactions [26]. At this stage in the design process, an anti-foamer will not be included due to the risk of decreasing scalant efficacy, and the likelihood that foam will not be an issue in the desalination plant.

Multistage Flash Distillation

The main objective of the design project is desalinate water. This is done with the main process of multi stage flash distillation (MSF). MSF can be developed using a numerous number of different process configurations, such as Once-Through, Simple Mixer Brine Circulation, and Multi-Stage Heat Rejection Brine Circulation processes.

The most desired process for the project is the Three Stage Heat Rejection Brine Circulation as it builds on benefits of the other simpler technologies. By combining principles of heat rejection and heat recovery, the required heat transfer area of the process is greatly reduced as compared to once through processes or simple brine recycle processes. It has the highest performance ratio with the lowest specific feed flow rates, therefore greatly lowering the operating costs of the process. It is also known as the industry standard for MSF[26]. In addition, since our brine disposal technique involves the pumping of the brine into a Class I well, the high brine outlet salinity is not a drawback for our process since post treatment or dilution of the brine is not necessary.

Post Treatment

After processing the water via multi-stage flash, the water needs to be post-treated to make the water taste as consumers would expect, since distilled water is “flat” and unpleasant, as well as to protect the consumers and the piping through which the water will be passing[27]. There are multiple alternatives to achieve these objectives of remineralization, aeration, corrosion control, and disinfection.

Aerating and introducing some dissolved solids back into the product water are effective ways to create a quality product that is not flat, and contains flavoring that is expected of the water when delivered to the consumer. Aeration will be accomplished via an inline spray aerator which will take up less space than cascade aeration.[28] Feed blending will be used to remineralize the water as opposed to a remineralization filter because it does not require additional equipment purchases, and can easily handle the large amounts of throughput required for the process.[27]

Corrosion and pH can be controlled by adding lime (calcium hydroxide) and carbon dioxide to the water. To do so, about 74 mg/L of lime and 88mg/L of CO2 should be added to the desalinated water to help prevent corrosion and increase alkalinity within acceptable ranges. Sodium hydroxide, soda ash, and sodium bicarbonate are alternatives to altering the alkalinity and pH of the product water, but lime and CO2 is an industry standard [16].

Disinfection needs to be done to prevent microbial growth in the desalinated water and ensure the safety of the general public. Chlorine addition via chlorine gas or sodium hypochlorite is the most common and only requires a dose of 1.5 to 2.5 mg/liter. [15] Other alternatives include ozonation, UV light, and chloramination. Chlorine, as a 5% - 15% sodium hypochlorite solution, is sufficient for our process and relatively inexpensive, and as such will be utilized in the process.

Transport of Brine to Well

Three major possibilities exist for transporting the brine from our desalination plant to the injection well for disposal: rail, trucking, and a pipeline. A pipeline was chosen as the most feasible and cost-effective approach.

A rail line is not available at this time, and with the cost to construct a rail line at approximately $43 million per mile[29], the enormous capital cost makes rail transport infeasible for this site. For large volume operations, pipelines are cheaper than trucking. In a study of wastewater sludge produced from wastewater treatment facilities, it was found that it was more economical for facilities producing over 1200 m3 per day to utilize pipelines rather than trucking.[30] Our facility is producing nearly 3 times this volume at 3485 m3 per day of brine. Furthermore, brine is a less viscous fluid than wastewater sludge, decreasing pumping costs in the pipeline and further amplifying the benefit of choosing a pipeline over an injection well.

Brine Storage

Due to the choice of a pipeline, rather than trucking, as the method of transport of brine to the injection well, brine storage is unnecessary, so storage solutions such as holding tanks were not investigated. One method of storage compatible with a pipeline is to pump the brine through an evaporation pond. This solution is attractive as it would allow the brine to concentrate, saving some costs of pumping, however, the considerable land usage of evaporation ponds leads them to only be effective for smaller plants. The largest municipal plant utilizing this method produces only 5.7 million liters per day[31], whereas our desalination plant is proposed to produce 75.7 million liters per day. Therefore, evaporation ponds have been eliminated from consideration.

Major Specifications

Material of Construction Selection

While saltwater and desalinated water in general can be corrosive, there are best practices within the desalination industry for material selection. With this in mind, best practice shows carbon steel lifetime can be lengthened by monitoring the oxygen concentration in the water, specifying the paint used to coat any metal, and more expensive materials can be used in areas of extremely high corrosion.[20]. By following these best practices, it is possible to save significant amounts of money through the use of carbon steel in most areas of the plant, with specific high-corrosion areas being reinforced with, or replaced with, more corrosion resistant materials, such as Cu/Ni 70/30 alloy[26].

Heat Exchanger Sizing

See Appendix F for heat exchanger sizing data. Heat exchanger sizes appear reasonable for placement in the flash vessels.

Flash Vessel Sizing

The dimensions for the flash drums were obtained through literature values. The flash drums were determined to be 18x4x3 m in width, height, and length.[26]

Wall thickness was determined using the following conventions: Design pressure is 10% more than the operating pressure, design temperature is 50°F (27.8°C) higher than the operating temperature, a corrosion allowance of 3-mm and an effectiveness of 85% was derived from the assumption of a double-welded butt joint that was spot checked. See Appendix G for wall thicknesses calculated for each pressure vessel.

The sizing of the vessels to be constructed will be determined after talks with a manufacturer. Due to economies of scale, it may be more cost-effective to buy 21 pressure vessels with the dimensions mentioned above and a wall thickness of 17.1-mm, the highest wall thickness required in the system.

Pipe Losses and Pressure Drop

HYSYS was used to estimate the diameter of a pipe given a specified pressure drop per 100m of pipe. It was determined that for a pressure drop of 0.1 kPa/100m of pipe, a 3.05m diameter pipe is sufficient, which is more than manageable for manufacturers. This pressure drop is mostly insignificant and will be taken care of with the safety factors included in the pumps. The significant pressure drops in our system is accounted for via losses in the flash vessels and heat exchangers, which drive the flash process. Therefore overall pipe losses are insignificant and are built into intentional design losses.

Economic Analysis

Economic Assumptions

The sale of purified water yields a revenue stream of $49.5 million per year assuming sale to commercial entities within the city limits of Corpus Christi at $1.7915 per thousand liters.[32] The primary variable costs are utilities and the brine disposal, with minimal raw materials costs due to the primary feedstock, seawater, being free, and minimal amounts of pre- and post-treatment chemicals being used. The cost of brine disposal used in this analysis was high at $2.097 per thousand liters[33], an estimate for brine disposal utilizing trucking as the mode of transport. As has been shown through previous analyses, a lower cost can be achieved using a direct pipeline, however, no good estimates for this cost could be found.

The NPV was calculated using a 6% cost of capital, the approximate interest rate for a municipal bond.[34] It was assumed that the plant can be built within two years, with production at half-scale in its first year. Additionally, one month of variable costs, $10.6 million, was set aside for working capital. See Appendix H for a full table of assumptions. A 30 year NPV calculation was chosen as the decision basis since 30 years is a conservative estimate for the lifetime of a desalination plant [35]. See below for estimates of NPV for the lifetime of the plant under various assumptions and design criteria.

Optimization and Sensitivity Analysis

Looking at the multi-stage flash process, there are a number of opportunities to optimize the process. The major process variables that were investigated were the inlet water temperature, the operating pressure drop per vessel, and the number of stages over which the process takes place. Considering these optimizations, our final process consists of 21 flash vessels (18 heat recovery and 3 heat rejection stages), each with a pressure drop of 5 kPa. See Appendix D for a screenshot of the HYSYS simulation used to model the optimized process.

Operating Pressure and Pressure Drop

Initially our process was designed to pump the inlet seawater and brine to a pressure of 2 bar and allow the pressure drop in each flash stage to end our process downstream at 1 bar to prevent complications associated with designing a system under vacuum. While this provided pumping advantages, the energy in the system was significantly higher due to vapor pressure considerations. Due to this fact, the required heat exchange area for certain exchangers proved to be infeasible (on the order of 80,000m2) due to the enormous capital and operating costs that would be associated with such a large heat exchanger.

The process was optimized to operate under vacuum, requiring additional pumping requirements but much lower required heat exchange area, and therefore lower utility costs. This optimization was done by specifying the pressure of the final flash vessel to 5.7kPa, so that the temperature of the water vapor (~30oC) is within approximately 5oC of the cooling water (35oC) so that condensation can occur within a reasonable approach. This also allows our system to optimally extract pure water from the brine running through the system and reduce energy requirements for cooling the product or the recycle. Our system redesign and optimization reduced the energy in the system and reduce the same heat exchanger area requirements by more than 3 orders of magnitude to approximately 800m2.

Once the process was optimized to operate in a vacuum, the pressure drop per flash stage regulated through values was then optimized. Three pressure drops per stages, 3kPa, 5kPa, and 7kPa, were tested and then an economic analysis was conducted to find the optimal value for the pressure drop. These changes had impacts on both operating and capital costs as they would change initial pumping requirements, the amount of water flowing through the process and recycle (and therefore the flash vessel sizes, heat exchanger sizing), and the efficiency of each stage.

The various pressure drops (3 kPa, 5 kPa, and 7 kPa) were tested on a system nominally at 24 stages under the assumption that the results would be generalizable to systems with a different number of stages. With increasing pressure drop, we found decreased capital cost but increased utility cost. As can be seen from Table 2 below, a pressure drop of 5 kPa proved to be the best option based on 30 year NPV, with a loss of $838.8 million, a savings of $65.5 million compared to the next-best option with a pressure drop of 7 kPa.

Table 2: Comparison of profitability for our MSF desalination process with 24 stages with 3 different pressure drops per stage
Number of Stages
 
Pressure Drop
(kPa)
Capital Cost
($MM)
Utility Cost
($MM/yr)
30-Year NPV
($MM)
NPV Ratio
(over 5kPa)
24 3 362.3 39.1 -905.8 1.08
24 5 255.1 53.6 -838.8 1.00
24 7 209.5 72.2 -904.3 1.08

Number of Flash Stages

The number of stages is an important area for optimization. An increased number of stages yields better recovery of purified water, however, requires higher capital cost from the additional pressure vessel. Furthermore, with an increased amount of purified water comes increasingly concentrated brine. This must be taken into account since any brine concentration in excess of about 7% presents a more significant corrosion risk[26], so increased maintenance costs for the piping or higher capital costs for more corrosion-resistant materials could be necessary for brine concentrations exceeding 7%. Therefore, to recover the same amount of pure water without exceeding corrosion limitations, increasing the number of stages will reduce the overall size of each stage.

Optimizing based on NPV, it was found that 21 stages is optimal, balancing the increased profits from the additional purified water additional costs of higher capital cost. See Table 3 below to compare the 30-year NPV of the process across various numbers of flash vessels.

Table 3: Comparison of profitability for our MSF desalination process with a 5 kPa pressure drop, 5000 m3/hr feed flow rate, with varying number of stages.
Number of Stages
 
Pressure Drop
(kPa)
Capital Cost
($MM)
Utility Cost
($MM/yr)
30-Year NPV
($MM)
NPV Ratio
(over 21 Stages)
17 5 213.9 58.7 -813.8 1.016
18 5 218 57.6 -809.9 1.011
19 5 224.3 58 -806.1 1.007
20 5 229.8 57.9 -813.6 1.016
21 5 226.6 55.9 -800.7 1
22 5 254.7 54.6 -849.5 1.061
23 5 249.3 54.1 -833.1 1.04
24 5 255.1 53.6 -838.8 1.048
25 5 254.9 52.7 -837.4 1.046

Inlet Seawater Temperature

By pairing our desalination plant with a natural gas power plant and utilizing its cooling water we forgo initial heating of our inlet stream. Normally, water pumped from the ocean would be approximately 25oC and by capturing waste heat from the power plant we can reduce utilities with our water inlet of 45oC. Through an economic comparison between two plants nominally at 21 flash stages, the plant with an inlet temperature at 25oC has a capital cost of $245MM and a utility cost of $77MM/yr and the same facility with an inlet water temperature at 45oC has a capital cost of only $226MM and a utility cost of $56MM/yr. As shown in Table 4 below, this $19MM savings in capital costs and $21MM/yr saving in utilities is largely due to reducing the size of the heat exchangers and lowering the steam required for heating duty on the inlet seawater respectively. Therefore our process is optimized by recovering the waste heat water from the gas fired power plant.

Table 4: Seawater Inlet Temperature Process Cost Optimization
Seawater Temperature
(°C)
Capital Cost
($MM)
Utility Cost
($MM/yr)
25 245 77
45 226 56
Savings 56 19

Overall Process Economics

After optimization at fixed flow rates, the process was scaled to meet the the 67% operating percentage and final product definitions as shown in Table 1, which resulted in finalized economics shown in Table 5 below. For a table of the installed costs of each process vessel, see Appendix I. For the finalized NPV calculations, see Appendix J.

Table 5: Summarized Economics for 21-stage MSFD Process
Economic Parameter Cost
(USD)
Capital Cost 345 MM
Total Operating Cost per Year 103 MM
Utility Cost per Year 59 MM
30-Year NPV (6% Discount) -1035 MM

Conclusions and Recommendations

Project Viability

Table 5 above demonstrates that the process has reasonable operating and capital costs, but the 30-year NPV is negative by -1035 $MM due to the extremely low sell price capability of desalinated water as a product. Therefore, this plant would have to heavily be supported by the City of Corpus Christi to run as the product revenue will not make it self-sufficient. The acquisition of government subsidies are key operating requirements for all desalination facilities in the United States.

Additional Concerns

Large volumes of water, steam, and energy are needed to ensure the project runs as specified. While most of the water can easily be extracted from the ocean with little to consequence, the fuel used to generate the steam and electricity can have a significant environmental impact. As the plant is located next to a natural gas power plant, this fuel is better than coal with respect to environmental concerns, and utilizing energy from the power plant to preheat the feed stream for the desalination plant helps lower environmental impacts.

The large amounts of high pressure steam being used represents one of the the largest safety concern in the process, because a high pressure steam release could easily cause severe burns or even death. Proper precautions and control measures must be in place to prevent accidental release. Otherwise, the process does not utilize any known toxic chemicals and is relatively safe from a chemical standpoint. The flash vessels mostly operate below atmospheric pressure, so they must be constructed as vessels that can withstand vacuum without failing.


Appendix A: Proposed Location of Desalination Plant

Pictured below is the proposed location for the desalination plant, located on Nueces Bay in Corpus Christi, adjacent to the Nueces Bay Energy Center. The plant’s proposed location is shown in the area outlined by the small circle in the upper right of the figure.

Nueces Bay Desalination Facility Location
Figure A.1: Proposed mapped location of Nueces Bay Desalination Facility.
Nueces Bay Desalination Facility Distance to Injection Well
Figure A.2: Mapped distance from proposed location to Class I Injection Well

Appendix B: Feed and Product Definitions - Salinity

Table 6: Average Composition of Total Dissolved Solids in Seawater[36][37]
Compound
 
Mass Composition
(kPa)
Chlorine 55.03%
Sodium 30.64%
Sulfate 7.70%
Magnesium 3.66%
Calcium 1.17%
Potassium 1.12%
Bicarbonate 0.36%
Bromine 0.19%
Other 0.15%
Nueces Bay Salinity Tracking
Figure C.1: Salinity in Nueces Bay over the past 10 years[7].

Appendix C: Process Flow Diagram

Process Flow Diagram
Figure C.1: Process Flow Diagram

Appendix D: HYSYS Simulation Model

HYSYS Simulation Model
Figure D.1: Screenshot of HYSYS Model Simulation.

Appendix E: Stream Tables

A summary of some values is shown below:

Table 7: Key process material streams
  Stream
 
Molar Flow
(105 kgmole/h)
Mass Flow
(105 kg/h)
Inlet Feed Water 454 83.6
Outlet Brine Reject 1.90 36.0
Product Pure Water 2.64 47.5


Table 8: Key process energy streams
Stream
 
Heat Flow
(kJ/h)
Feed Water 1.30E+11
Q-301 5.73E+06
Q-302 3.09E+09
Q-304 4.68E+06
Q-303 -1.26E+09
Brine Reject -5.47E+10
Pure Water -7.46E+10

(Negative value denotes energy leaving process)

Appendix F: Heat Exchanger Sizing

Table 9: Utility Temperatures and Heat Transfer Coefficient[38]
  HP Steam Cooling Water
Temperature (°C) 250 35
U (W/m2K) 4000 1500
Table 10: Internal Flash Heat Exchanger Sizing, condensing steam.
Exchanger UA
(kJ/°C-h)
U
(kJ/hr/m2°C)
A
(m2)
E-101 1.47E+07 14400 1019
E-102 1.53E+07 14400 1059
E-103 1.59E+07 14400 1103
E-104 1.66E+07 14400 1153
E-105 1.74E+07 14400 1209
E-106 1.83E+07 14400 1272
E-107 1.93E+07 14400 1342
E-108 2.05E+07 14400 1424
E-109 2.19E+07 14400 1518
E-110 2.35E+07 14400 1629
E-111 2.54E+07 14400 1761
E-112 2.77E+07 14400 1921
E-113 3.05E+07 14400 2119
E-114 3.42E+07 14400 2372
E-115 3.90E+07 14400 2706
E-116 4.56E+07 14400 3167
E-117 5.55E+07 14400 3856
E-118 7.20E+07 14400 5000


Table 11: Heat Exchanger Sizing for Process Heaters and Coolers
Exchanger Q
(kJ/h)
U
(J/s/m2K)
U
(kJ/hr/m2K)
LMTD
 
A
(m2)
E-201 9.67E+08 1500 5400 16.03 11165
E-202 1.26E+09 1500 5400 7.57 30921
E-203 1.88E+09 1500 5400 0.45 77366
E-302 3.09E+09 4000 14400 155 1385
E-303 1.26E+09 4000 14400 209.5 418

The high heat transfer area in the final cooler of the heat rejection stage is due to the close approach temperature.
Other cooling / pressurization techniques will be used to reduce the area.

Appendix G: Pressure Vessel Sizing

Table 12: Operating temperature and pressure and corresponding thickness for flash vessels
Unit Temperature
(°C)
Pressure
(kPa)
Thickness
(mm)
V-101 103.6 110.7 17.14
V-102 102.3 105.7 16.62
V-103 100.9 100.7 16.10
V-104 99.5 95.7 15.58
V-105 98.0 90.7 15.06
V-106 96.4 85.7 14.53
V-107 94.8 80.7 14.01
V-108 93.1 75.7 13.49
V-109 91.3 70.7 12.97
V-110 89.3 65.7 12.45
V-111 87.3 60.7 11.93
V-112 85.1 55.7 11.41
V-113 82.7 50.7 10.89
V-114 80.1 45.7 10.36
V-115 77.3 40.7 9.84
V-116 74.1 35.7 9.32
V-117 70.6 30.7 8.80
V-118 66.5 25.7 8.28
V-201 61.7 20.7 7.76
V-202 55.8 15.7 7.24
V-203 47.9 10.7 6.72

Appendix H: Expanded Economic Assumptions

Table 13: Product and raw material market prices
Parameter Value/Unit Unit
Sale price of water[32] $0.0021 liter
Brine disposal[33] $0.0016 barrel
Belgard EV 2030[39] $1.99 kilogram
Sodium Hypochlorite 12%[40] $4.54 kilogram
Lime[41] $0.09 kilogram
CO2[42] $0.04 kilogram


Additional Economic Assumptions

  • 6% cost of capital
  • Construction of plant in 2 years, 50% of full-scale production in 3rd year
  • 35% tax rate with 5 year MACRS depreciation
  • 5 operators per shift with 3 shifts
  • $50,000 salary per operator
  • Supervision is 25% operating labor
  • Direct overhead is 45% of labor & supervision
  • Maintenance is 3% of ISBL investment per year
  • Plant overhead is 65% of labor and maintenance
  • Screen price negligible (~$2,000)

Appendix I: Equipment Cost Summary

Table 14: Installed costs of all major process equipment, in USD.
Unit Equipment Cost
(USD)
Installed Cost
(USD)
Equipment Weight
(LBS)
Total Installed Weight
(LBS)
E-101 1033900 1716400 403500 568790
E-102 1065700 1748700 416500 581960
E-103 1131500 1835900 439800 609338
E-104 1206900 1913200 469800 639902
E-105 1238900 1945800 483000 653292
E-106 1315000 2023500 515400 686222
E-107 1058900 1741900 413000 578460
E-108 1447500 2458400 564900 796324
E-109 1526200 2540200 598500 830924
E-110 1656600 2698900 646400 883959
E-111 1833500 2900600 714600 953808
E-112 1974700 3046000 774000 1014446
E-113 2186200 3647000 856000 1154275
E-114 2483100 4018400 968400 1278580
E-115 2817800 4433900 1103700 1431085
E-116 3291100 5778100 1290000 1731000
E-117 4062000 6880400 1588400 2081273
E-118 5361900 10603700 2097500 3054252
E-201 1682100 2649700 633600 835319
E-202 3265400 5677900 1233000 1643496
P-301 8263300 10579300 593100 1016878
P-302 5435000 7740400 389400 811881
V-101 43800 221900 11900 40680
V-102 2070900 5175400 1051900 1717877
V-103 1759900 4866600 804500 1476730
V-104 2976300 6117800 1625400 2292006
V-105 32200 201500 8300 35146
V-106 3480300 6698800 1863900 2546114
V-107 3538500 6800500 1918700 2612432
V-108 3673200 6973400 1985400 2687585
V-109 4178000 7524400 2228400 2938816
V-110 3690700 6978300 1994800 2693811
V-111 3711900 6991200 1986700 2683352
V-112 3541500 6754700 1891600 2562046
V-113 3288600 6463300 1782100 2444134
V-114 3039500 6176100 1651800 2306017
V-115 2961900 5572100 1614900 2161959
V-117 2831600 5403700 1549900 2087670
V-118 2800000 5359400 1531200 2065331
V-201 2807200 5147700 1535700 2002614
V-202 2921700 5295200 1587700 2063167
V-203 6322000 9725700 3364500 4063966

Appendix J: Economic NPV Analysis

Economic Analysis
Figure J.1: Screenshot of process economic analysis.

References

  1. ^ Tapping the oceans. The Economist USA. http://www.economist.com/node/11484059. Accessed March 2, 2016.
  2. ^ Water Supply in the US. EPA. http://www3.epa.gov/watersense/pubs/supply.html. Accessed March 2, 2016.
  3. ^ Stage 2 Measures in the Drought Contingency Plan. Available at http://www.cctexas.com/government/water/conservation/conservation-drought-plans/stage-2-measures. Accessed January 12, 2016.
  4. ^ Corpus Christi Desalination Demonstration Project. Available at http://www.cctexas.com/Assets/Departments/Water/Files/DesalFactSheet.pdf. Published June 2014. Accessed January 12, 2016.
  5. ^ Torcellini P, Long N, Judkoff R. Consumptive Water Use for U.S. Power Consumption. NREL. 2003; TP-550-33905.
  6. ^ Stations Map & Real - Time Data. The Conrad Blucher Institute for Surveying and Science website. Available at http://www.cbi.tamucc.edu/cbi/data/. Updated January 2016. Accessed January 9, 2016.
  7. ^ a b Definition and Units. CATD Salinity Expertise Center. Available at http://www.salinityremotesensing.ifremer.fr/home. Accessed January 12, 2016.
  8. ^ Brown E, Colling A, Park D, Phillips J, Rothery D, Wright J. Seawater : Its Composition, Properties and Behaviour. Boston: Butterworth-Heinemann, 1995.
  9. ^ Texas Water Code. Availabe at http://www.statutes.legis.state.tx.us/Docs/WA/htm/WA.27.htm. Accessed January 14, 2016.
  10. ^ Google Maps. Available at https://goo.gl/maps/3xcvLZwUCe42 Accessed January 15, 2016.
  11. ^ EPA Regulations on Class I Wells. Available at http://www.epa.gov/uic/class-i-industrial-and-municipal-waste-disposal-wells. Accessed January 14, 2016.
  12. ^ List of Injection Well Facilities by Location. Available at http://www.ehso.com/cssepa/tsdfdeepwells.php. Accessed January 14, 2016.
  13. ^ Climate Corpus Christi- Texas. US Climate Data. Available at http://www.usclimatedata.com/climate/corpus-christi/texas/united-states/ustx0294. Accessed January 12, 2016.
  14. ^ a b BWA Water Additives. Belgard EV2030 Technical Data Sheet. BWA Water Additives. http://www.wateradditives.com/files/products/tech_data_sheets/Belgard%20EV%202030_Technical%20Data%20Sheet_Thermal_8.5x11.pdf. Accessed January 27, 2016.
  15. ^ a b World Health Organization. Desalination for safe water supply. http://www.who.int/water_sanitation_health/gdwqrevision/desalination.pdf. Accessed January 26, 2016.
  16. ^ a b Vouchkov, N. Re-Mineralization of Desalinated Water. SunCam. https://s3.amazonaws.com/suncam/npdocs/118.pdf. Accessed February 18, 2016.
  17. ^ Stage 2 Measures in the Drought Contingency Plan. Available at http://www.cctexas.com/government/water/conservation/conservation-drought-plans/stage-2-measures. Accessed January 12, 2016.
  18. ^ Fritzman C, Lowenberg J, Wintgens T, Melin T. State-of-the-art Reverse Osmosis Desalination. Desalination. 2007; 216:1-76.
  19. ^ El-Dessouky H., Alatiqi I, Ettouney H. Process synthesis: The multi-stage flash desalination system. Desalination. 1998;115(2):115-179. doi: 10.1016/S0011-9164(98)00035-6.
  20. ^ a b c d Morris, R. The development of the multi-stage flash distillation process: A designer's viewpoint. Desalination. 1993;93(1-3):57-68. doi:10.1016/S0011-9164(93)80096-6. Availble at http://www.sciencedirect.com/science/article/pii/0011916493800966
  21. ^ Al-Gobaisi, D. A quarter-century of seawater desalination by large multistage flash plants in Abu Dhabi (Plant performance analysis, assessment, present efforts toward enhancement and future hopes). Desalination. 1994;99(2-3):509-512. doi: 10.1016/S0011-9164(94)00196-0.
  22. ^ NSF International. NSF Product and Service Listings: Drinking Water Treatment Chemicals - Health Effects. NSF International. http://info.nsf.org/Certified/PwsChemicals/Listings.asp?Company=00300&. Accessed January 27, 2016.
  23. ^ BWA Water Additives. Belgard EV2035 Technical Data Sheet. BWA Water Additives. http://www.wateradditives.com/files/products/tech_data_sheets/Belgard%20EV2035_Technical%20Data%20Sheet_Thermal_8.5x11.pdf. Accessed January 27, 2016.
  24. ^ BioLab Water Additives. Belgard EV Antiscalant for seawater distillation plants. BioLab Water Additives. http://www.lpq.com.mx/pdf/BELGARD%20EV.PDF. Accessed January 27, 2016.
  25. ^ Edwards - Hick Hargreaves. Seawater Deaerators. Edwards - Hick Hargreaves. http://psscorp.co.th/upload/news/20110830105340.pdf. Accessed January 26, 2016.
  26. ^ a b c d Kansas State University ChE 413. Available at: http://faculty.ksu.edu.sa/Almutaz/Documents/ChE-413/Multi-stage%20Flash%20Desalination.pdf. Accessed January 26, 2016.
  27. ^ a b Clayton R. A review of current knowledge: Desalination for water supply. Foundation for Water Research. http://www.fwr.org/desal.pdf. Accessed January 26, 2016.
  28. ^ Minnesota Rural Water Association. Aeration. http://www.mrwa.com/WaterWorksMnl/Chapter%2011%20Aeration.pdf. Accessed January 26, 2016.
  29. ^ About Money. How Much Do Rail Transit Projects Cost to Build and Operate? 2014. Available at: http://publictransport.about.com/od/Transit_Projects/a/How-Much-Do-Rail-Transit-Projects-Cost-To-Build-And-Operate.htm. Accessed January 27, 2016.
  30. ^ Marufuzzaman M, Eskioglu S, Hernandez R. Truck versus pipeline transportation cost analysis of wastewater sludge. Transportation Research. 2015; 74(A): 14-30.
  31. ^ University of Santa Cruz Center for Integrated Water Research. Concentrate Management: Evaporation Ponds. 2010. Available at: https://ciwr.ucsc.edu/sites/default/files/ICM_D5.pdf. Accessed January 27, 2016.
  32. ^ a b Water schedule. City of Corpus Christi Utility Business Office. http://www.cctexas.com/Assets/Departments/Financial-Services/Utilities-Business-Office/files/waterrates.pdf Accessed February 28, 2016.
  33. ^ a b McCurdy, R. Underground injection wells for produced water disposal. Chesapeake Energy Corporation. http://www.epa.gov/sites/production/files/documents/21_McCurdy_-_UIC_Disposal_508.pdf Accessed February 28, 2016.
  34. ^ Zirbe, R.O. Jr., Han, X., Layton, D., Leshine, T. A history of discount rates and their use by government agencies. (2002). http://faculty.washington.edu/zerbe/docs/DISCOUNT%20RATE%20HISTORY-latesXIt.doc Accessed February 28, 2016.
  35. ^ Tampa Bay Seawater Desalination Plant. American Water. http://www.amwater.com/files/tampabayseawaterdesalinationplantcasestudy6.16.09.pdf. Accessed February 25, 20216.
  36. ^ Physical and Thermodynamic Data. In: Dickson AG, Goyet C. Handbook of Methods for the Analysis of the Various Parameters of the Carbon Dioxide System in Sea Water.
  37. ^ Composition of Seawater. Water Treatment of Solutions. Available at http://www.lenntech.com/composition-seawater.htm. Accessed January 12, 2016.
  38. ^ G.P. Towler, R. Sinnott. Chemical Engineering Design: Principles, Practice and Economics of Plant and Process Design. Elsevier, 2012.
  39. ^ Detailed import data of Belgard. Zauba. https://www.zauba.com/import-belgard-hs-code.html Accessed February 24, 2016.
  40. ^ High Quality Sodium Hypochlorite 12% solution Best Price. Alibaba Group. http://www.alibaba.com/product-detail/High-Quality-Sodium-Hypochlorite-12-solution_60355867621.html?spm=a2700.7724838.0.0.YHuHt3. Accessed March 7, 2016.
  41. ^ Alibaba. Hydrated Lime 93%. Alibaba Group. http://www.alibaba.com/product-detail/high-quality-hydrated-lime-for-water_60423352849.html?spm=a2700.7724838.30.31.BVcfrP. Accessed February 24, 2016.
  42. ^ Carbon Dioxide Advanced Oil Recovery. The American Oil & Gas Reporter. http://www.aogr.com/magazine/editors-choice/industrial-co2-supply-crucial-for-eor. Accessed February 28, 2016.